Panasonic MN101C00 User Manual
Page 112
Advertising
Chapter 5 Serial Functions
98
Figure 5-2-3 Synchronous Serial Interface Reception Timing
(reception at rising edge)
Figure 5-2-4 Synchronous Serial Interface Reception Timing
(reception at falling edge)
Synchronous Serial Interface
Clock
Start condition
disabled
Start condition
enabled
SC0BSY start
condition
enabled
SC0BSY start
condition
disabled
Interrupt
SC0LNG2 to 0
0
1
2
3
4
5
6
7
0
Clock
Start condition
enabled
Start condition
disabled
SC0BSY start
condition
disabled
SC0BSY start
condition
enabled
Interrupt
SC0LNG2 to 0
0
1
2
3
4
5
6
7
0
Advertising