2 ac zero-cross circuit operation, 2-1 setup and operation – Panasonic MN101C00 User Manual

Page 137

Advertising
background image

Chapter 7 AC Zero-Cross Circuit/Noise Filter

123

AC Zero-Cross Circuit Operation

7-2 AC Zero-Cross Circuit Operation

7-2-1 Setup and Operation

Settings for zero-cross circuit operation are listed below.

(1)

Set the REDG1 flag of the IRQ1ICR register to select the valid edge for IRQ1.

(2)

Set the NF1EN and NF1CK1 to 0 flags of the NFCTR register to set the noise filter

and its sampling clock.

(3)

With the P21IM flag of the FLOAT1 register, set the P21 pin to zero-cross

detection.

(4)

An IRQ1 interrupt is generated by the falling edge or the rising edge of AC

zero-cross detection output.

Actual IRQ interrupt requests will be generated multiple times. Therefore, the software must

filter this signal before making any evaluations.

When noise filtering is selected for use, the amount of evaluation processing by the software

will be reduced. However, if the OSC stops, a return from the backup mode will not be

possible.

V

DD

V

SS

AC line waveform

Point A

Ideal
IRQ1

Actual
IRQ1

10 ms at 50Hz

8.3 ms at 60Hz

Figure 7-2-1 AC Line Waveform and IRQ Generation Timing