Chapter 6 A/D Conversion Functions

118

A/D Converter Control Registers

6-3-2 A/D Control Register (ANCTR)

This readable and writable 8-bit register controls the operation of the A/D

converter.

(1) A/D control register 0 (ANCTR0)

1:Specify that where the period of the A/D conversion clock

is greater than 800ns.

2:Sample-and-hold time is determined by the analog input

impedance. T

AD

indicates the period of the A/D conversion

clock.

Figure 6-3-1 A/D Control Register 0 (ANCTR0: X'03F90', R/W)

0

1

0

1

0

1

A/D conversion

clock selection

1

0

0

1

0

0

1

1

Analog input selection

0

1

2

4

5

6

7

3

ANCTR0

ANCHS0

ANCHS1

ANCHS2

ANCHS0

ANCHS1

ANCHS2

ANLADE

ANLADE

ANCK0

ANCK1

ANCK0

ANCK1

ANSH1

ANSH0

ANSH0

ANSH1

AN0

AN1

AN2

AN3

AN4

AN5

AN6

AN7

0

1

1

0

0

1

1

0

1

A/D ladder resistor control

A/D ladder resistors off

A/D ladder resistors on

fs/2

fs/4

fs/8

Use prohibited

0

1

0

1

0

1

Sample and

hold time setting

2

T

AD

×

2

T

AD

×

6

T

AD

×

18

Use prohibited

(at reset: XXXX0XXX)