Peripheral equipment, Appendixes, Power – Panasonic MDDDT5540 User Manual

Page 77: Circuit breaker, Noise filter, Environment

Advertising
background image

- App. 3 -

Appendixes

Power

Single-phase 100V : Single-phase 100 to 115V +10%/-15%, 50/60Hz

Single-phase 200V : Single-phase 200 to 230V +10%/-15%, 50/60Hz

Three-phase 200V : Three-phase 200 to 230V +10%/-15%, 50/60Hz

(1) Use under the environment of Over-voltage Category III specified by IEC60664-1.

(2) The power for interface should be marked CE or appropriate EN Standard type, 12VDC to

24VDC, insulated.

Circuit Breaker

Install a circuit breaker between the power supply and noise filter. The circuit breaker should

be IEC Standard and UL listed marked.

Noise Filter

If several amplifiers are used, and a single noise filter is installed at the power supply, consult

the manufacturer of the noise filter.

Peripheral Equipment

Environment

The servo amplifier should be used under Contamination Level 2 or 1 specified by IEC60664-
1 (housing the amplifier in an IP54 control box).

Control box

Controller

Insulated power
for interface

Power

Circuit
breaker

Surge

absorber

Noise filter

Noise filter for
signal lines

Protective earth (PE)

L1

U

CN–I/F

CN–SIG

M

RE

V
W
E

L2
L3

Noise filter for
signal lines

AC servo
amplifier

AC servo
motor

Advertising
This manual is related to the following products: