Appendixes – Panasonic MDDDT5540 User Manual

Page 85

Advertising
background image

- App. 11 -

Appendixes

After an Alarm event (during Servo-ON)

*1. The value of t1 is the value of Pr6B or the time needed for decreasing the motor speed

to approx. 30 r/min, which is shorter.

*2. For the operation of the dynamic brake following an alarm event, see the explanation of

Pr68 in "Details of Parameters".

Alarm

Dynamic brake

Motor energized

Normal

Energized

Not alarm

Error (alarmed)

Operation (braking) 2

Not energized

Alarm

Servo alarm
(ALM)

approx.1 to 5 ms

t1 1

Operation (OFF)

Operation (OFF)

Released (ON)

approx. 30 r/min

approx. 30 r/min

Released (ON)

A

B

Brake release
(BRK-OFF)

t1 1

Set by Pr6B

Set by Pr6B

Advertising