Replacing the Light-Source Lamp (Cont.)

Loosen the lamp-unit screws, raise

the handle, and pull out the lamp

unit.

Loosen the two screws with a flat-end screwdriver.

Screw

The screws are fitted so that they do not come off the lamp-

unit.

Lamp unit

Insert the new lamp unit fully
inside and fasten the screws.

Fasten the two screws with a flat-end screwdriver.

Do not touch the glass surface of the light-source lamp

directly with your hand as well as staining it. If you touch
with a bare hand, stains on your hand may adhere to the
lamp, possibly preventing the lamp from performing as
specified due to a shortened lamp life, a darkened screen,
etc. To handle a new light-source lamp, hold its plastic
part. Never touch the metal part or the front glass
surface.

S c r e w

Handle

Replace the lamp-replacement

opening cover and fasten the
screws.

Fasten the two screws with a flat-end screwdriver.

Handle

Lamp unit

Lamp-replacement
opening cover

Be careful not to
damage the claw.

Install the lamp unit and close the lamp-replacement opening cover correctly; otherwise, a safety switch is activated

to prevent the projector from operating.

If the claw on the lamp-replacement opening cover is damaged, the projector may not possibly operate. Then, replace
with a new lamp-replacement opening cover.
After replacing the lamp, be sure to reset the lamp use time (see page 52).