V.35 technical information, General v.35 information, Serial interface control signals – Polycom ViewStation User Manual

Page 209

Advertising
background image

© Polycom, Inc.

193

ViewStation User Guide

C

V.35 Technical Information

General V.35 Information

The ViewStation is designed to be compatible with tested network
equipment without any modification from the user. If your network
equipment varies from conventional V.35 video implementations,
you can adjust the operation of the signals. Use the following
technical information with information provided by your network
equipment vendor to customize your V.35 interface.

Serial Interface Control Signals

The following table describes the configuration of each signal.

Signal

(Cable Pin)

Direction

Description

Configuration Option

ST (TC/TT)

OUT

Send Timing
(clock)

Normal: falling edge sends data
Inverted: rising edge sends data

RT (RC)

IN

Receive Timing
(clock)

Normal: rising edge receives data
Inverted: falling edge receives data

RTS (RTS)

OUT

Request To Send

Normal: high voltage is logic 1
Inverted: low voltage is logic 1

DCD (DCD)

IN

Data Carrier
Detect

Normal: high voltage is logic 1
Inverted: low voltage is logic 1

Filter: allow DCD to drop for 60 seconds
before changing call state

CTS (CTS)

IN

Clear To Send

Normal: high voltage is logic 1
Inverted: low voltage is logic 1

DTR (DTR)

OUT

Data Terminal
Ready

Normal: high voltage is logic 1
Inverted: low voltage is logic 1

On: constant high voltage

Note: if set to ON, inverted is not an
option.

DSR (DSR)

IN

Data Set Ready

Normal: high voltage is logic 1
Inverted: low voltage is logic 1

Answer: Use DSR as a Ring-In indicator

Advertising