2-6 System Administrator’s Guide

Sensors

Use this option to view the black mark, die cut, on-demand, and aperture
sensor settings.

To exit, press

F at any time.

1. From the Diagnostics menu, select Printer, Sensors, Black Mark.

Black

Mark

A/D Value = 170

The acceptable range is between 0 to 255 and the A/D values
change as supply moves past the sensors. The count changes by
at least 25 steps when a black mark is under the sensor. If you
do not notice at least a 25-step difference, you may need to call
Service.

Note: A/D value will increase by 25 steps or more from label to die cut.

2. Press

F to return to the Sensors menu.

3. Select Die Cut.

Die

Cut

A/D Value = 170

The acceptable range is between 0 to 255 and the A/D values
change as supply moves past the sensors. The count changes by
at least 50 steps when die cut labels move through the sensor. If
you do not notice at least a 50-step difference, you may need to
call Service.

Note: A/D value will decrease by 50 steps or more from label to die cut.

4. Press

F to return to the Sensors menu.