Rs-485 setting, Internal diagram – Panasonic WV-CLR920A User Manual

Page 16

Advertising
background image

RS-485 Setting

Follow the procedures as below.

1. Slide the panel to the left until it locks.
2. Set RS-485 Termination Switch to RS485 LINE

TERM for the furthermost camera from the RS232C/
RS485 converter and Hi-Z for the other camera.
Initial factory setting is RS485 LINE TERM.

3. Select protocol by sliding triple full duplex/half

duplex selection switches simultaneously.
Initial factory settings are 4-line.

Notes:

• BP stands for Bit Position.
• Daisy chain connection is not available for full

duplex.

Switch
Position

-16-

Internal Diagram

T (B)

T (A)

R (B)

R (A)

GND

T (B)

T (A)

R (B)

R (A)

GND

Data Transmission

Data Reception

Data Transmission

Data Reception

RS485 Terminal
Control data is transmitted and received to and from
other peripherals.

Notes:

• Shielded, two twisted pairs cable
• Low impedance
• Wire gauge size is thicker than AWG#22

(0.33 mm

2

)

<Half duplex>

<Full duplex>

RS-485 Termination Switch (BP 1)

Function

RS485 LINE TERM

Termination ON

Hi-Z

Hi-Z

BP 2

BP 3

BP 4

Function

Right

Right

Right

Half duplex (2-line)

Left

Left

Left

Full duplex (4-line)

Switch
Position

BP1
BP2
BP3
BP4