49

Changing EFX Settings

Through a specific set of number key presses, you can
customize the pause or cool down times.

To access the menu and change the settings, perform the
following steps:

1. At the Precor banner, press the following keys in

sequence without pausing between selections:

RESET, 5, 6, 7, 1

Numbers appear on the display as you press the
associated key.

DIAGS - SET PARAMETERS appears briefly, and then
SELECT UNITS scrolls across the display.

Selecting a U.S. Standard or Metric Display

The EFX can display measurements in either metric or U.S.
standard. The default factory setting is set to display U.S.
standard. To change this setting, perform the following steps:

2. At the SELECT UNITS prompt, press OK. Use the

navigational arrow keys to select a unit of measure (either
METRIC or U.S.).

3. When you are ready, press OK to accept the displayed

setting and move to the next program. Or, press RESET
to cancel any changes and return to the Precor banner.

Setting a Pause Time Limit

You can limit how long a user can pause while exercising on
the unit by entering a time between 1 and 10 minutes. For
example, if you set the pause time limit to 60 seconds, the
display automatically resets to the Precor banner if no key
press occurs within one minute.

4. At the SET MAX PAUSE TIME prompt, press OK. Use

the navigational arrow keys to change the time limit.
Choose between 1 and 10 minutes. The default time is
10 minutes.

5. When you are ready, press OK to accept the displayed

setting and move to the next program. Or, press RESET
to cancel any changes and return to the Precor banner.