Technical information, English, Mode) connection method – Panasonic PT-EW630U User Manual

Page 102: Command transmission method

Advertising
background image

Technical Information

102

- ENGLISH

Appendix

When WEB Control administrator rights password is not set (Non-protect

J

mode)

Connection method

z

Obtain the IP address and port number (Initial set value = 1 024) of the projector and

1 )

make a request for connection to the projector.

Acquire the IP address from the menu screen of the projector, and the port number from the WEB control

page.
IP address : Obtain from MAIN MENU → [Network] → [Network status]

Port No. :

Acquire from the WEB control “Detailed set up” → “Command port set up” page

There is a response from the projector.

2 )

Response data

Data section

Blank

Mode

Termination symbol

“NTCONTROL”

(ASCII string)

‘ ’

0x20

‘0’

0x30

(CR)

0x0d

9 bytes

1 byte

1 byte

1 byte

Mode : 0 = Non-protect mode

Command transmission method

z

Transmit by the following command format.
Transmitted data

Header

Data section

Termination symbol

‘0’

0x30

‘0’

0x30

Control command

(ASCII string)

(CR)

0x0d

1 byte

1 byte

Undefined length

1 byte

Receive data

Header

Data section

Termination symbol

‘0’

0x30

‘0’

0x30

Control command

(ASCII string)

(CR)

0x0d

1 byte

1 byte

Undefined length

1 byte

Receive data

Error message

Termination symbol

“ERR1”

“ERR2”

“ERR3”

“ERR4”

“ERR5”

“ERRA”

Undefined control command

Out of parameter range

Busy state or no-acceptable period

Timeout or no-acceptable period

Wrong data length

Password mismatch

(CR)

0x0d

4 bytes

1 byte