Technical information, English, Basic format – Panasonic PT-EW630U User Manual

Page 104: Basic format (with sub command)

Advertising
background image

Technical Information

104

- ENGLISH

Appendix

J

Basic format

Transmission from the computer begins with STX, then the command, parameter, and ETX are sent in this

order. Add parameters according to the details of control.

STX

C1 C2 C3

:

P1 P2

Pn

ETX

When sending commands without parameters, a colon (:) is not necessary.

:

J

Basic format (with sub command)

STX

C1 C2 C3

:

ETX

S1

S2

S3

S4

S5

E

P1

P2

P3

P4

P5

P6

When transmitting a command which does not need a parameter, the operation (E) and parameter are not

:

necessary.

End

(1 byte)

Parameter

(undefined length)

Colon

(1 byte)

3 command

characters

(3 bytes)

Start

(1 byte)

Parameter (6 bytes)

Symbol “+” or “-” (1 byte) and set value or

adjustment value (5 bytes)

Operation (1 byte)

“=” (Value specified using parameter is set)

Same as basic format

Sub command (5 bytes)

Advertising
This manual is related to the following products: