Maintenance, E-48, Replacing the lamp – Nikon HT1000 User Manual

Page 48

Advertising
background image

E-48

MAINTENANCE

This section describes the simple maintenance procedures you should
follow to replace the lamp, and to clean the cabinet and the lens.

Replacing the Lamp

After your lamp has been operating for 1500 hours (up to 2000 hours :
Eco mode) or longer, the "Lamp" indicator in the cabinet will blink red
and the message will appear. Even though the lamp may still be work-
ing, replace it at 1500 hours (up to 2000 hours : Eco mode) to maintain
optimal projector performance.

CAUTION
• DO NOT TOUCH THE LAMP immediately after it has been used.

It will be extremely hot. Turn the projector off, wait 90 seconds,
turn off the main power switch, and then disconnect the power
cable. Allow at least one hour for the lamp to cool before han-
dling.

• DO NOT REMOVE ANY SCREWS except the lamp cover screw

and two lamp case screws. You could receive an electric shock.

• The projector will turn off and go into stand by mode after 1600

hours (up to 2100 hours : Eco mode) of service. If this happens,
be sure to replace the lamp. If you continue to use the lamp after
1500 hours (up to 2000 hours : Eco mode) of use, the lamp bulb
may shatter, and pieces of glass may be scattered in the lamp
housing. Do not touch them as the pieces of glass may cause
injury.

If this happens, contact your NEC dealer for lamp replacement.

To replace the lamp:

1. Loosen the lamp cover screw until the screwdriver goes into a free-

wheeling condition and remove the lamp cover. The lamp cover screw
is not removable.

Interlock

2. Loosen the two screws securing the lamp housing until the screw-

driver goes into a freewheeling condition. The two screws are not
removable.

3. Remove the lamp housing by pulling out the handle.

NOTE: There is an interlock on this case to prevent the risk of electrical shock.
Do not attempt to circumvent this interlock.

4. Insert a new lamp housing until the lamp housing is plugged into the

socket.

CAUTION: Do not use a lamp other than the NEC replacement lamp
(LT60LP).

5. Secure it in place with the two screws.

Be sure to tighten the screws.

6. Reattach the lamp cover.

7. Tighten the lamp cover screw.

Be sure to tighten the screw.

8. After you install a new lamp, from the menu select [Projector Options]

[Setup]

[Page 4]

[Clear Lamp Hour Meter] to reset the lamp

usage hours.
If the projector will not be turned on after using 1600 hours (up to
2100 hours : Eco mode) of service, press and hold the [Help] button
on the remote control for ten seconds or longer to reset the lamp time
clock to zero.