National Instruments NI 9475 User Manual
Page 4

NI 9475 Operating Instructions and Specifications
4
ni.com
Caution
Substitution of components may impair
suitability for Class I, Division 2.
Caution
For Zone 2 applications, install the system
in an enclosure rated to at least IP 54 as defined by
IEC 60529 and EN 60529.
Caution
For Zone 2 applications, install a protection
device between the input signal and the NI 9475 input
pin. The device must prevent the input V
sup
-to-COM
voltage from exceeding 84 V if there is a transient
overvoltage condition.
Special Conditions for Hazardous Locations Use in Europe
This equipment has been evaluated as Ex nA IIC T4 equipment
under DEMKO Certificate No. 07 ATEX 0626664X. Each module
is marked
II 3G and is suitable for use in Zone 2 hazardous
locations. If you are using the NI 9475 in Gas Group IIC hazardous
locations or in ambient temperatures of –40 °C
≤ Ta ≤ 70 °C, you
must use the device in an NI chassis that has been evaluated as
EEx nC IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.