From the Port settings menu, the configuration of each port can be viewed and changed.

Setting

Description

Value

Port name

Change the port name

Max. 15 characters

Port type

Host or User

H or U

In-band disconnect
sequence

Select characters to use for in-
band disconnect sequence

1 + code for 1-character sequence (see Fig. 6 below)
3 + desired characters for 3-character sequence
0- for no disconnect sequence
T- display Control code list

Connection
Timeout

Time left before connection will be
broken due to receiver inactivity

0-90 minutes. If 0 is selected, the connection will
never timeout.

Serial settings

Display serial settings menu

N/a

Modem settings

Display modem settings menu

N/a

View port data
buffer

View the last 508 characters
received and transmitted to/from
the port

N/a

Clear port data
buffer

Clear the data buffer for the
selected port

N/a

VT100 displaying
delay

Modify the displaying extra delay

0 = None,1 = normal, 2 = double, or 3 = triple

"None" value can be used if the display is faster (i.e. with a
terminal emulator, like HyperTerminal, running on a PC); the
other values are useful if real terminals or slower serial
devices are used as user/administrator consoles.

Reset Port settings
to default

Restores factory default port
settings

A confirmation "Y" will be required


When [

3] is pressed to change the in-band disconnect sequence, the choices provided are 0, 1, 3, or T. Pressing a [T] will bring

up a Control code list containing key sequences used for 1-character sequences, and the ASCII codes associated with each.
(See Fig. 10) To set a 1-character sequence, press [

1], then the code from the table associated with the desired sequence.

Note: If the 3-character disconnect sequence is enabled, the string: [CR][LF]<3-char sequence>[CR][LF] has to be
received to break the connection (7 characters). The [CR] and [LF] ASCII characters stand for 13 and 10 decimal codes
(ASCII Carriage Return and Line Feed) respectively

.

FYI: If the 1-character sequence is
selected, the connected device will
not receive the disconnect character.
If the 3-character sequence is
selected, it will be sent to the
connected device, prior to breaking
the connection.














Figure 11- Control Codes for in-band disconnect sequence

-

When selecting each new port setting values, press [

Esc] or [Spacebar] to cancel, or press [Enter] to save.

-

Press [

>] (greater than symbol) to display the current settings for the next port.

-

Press [

<] (less than symbol) to display the current settings for the previous port

-

Press [

Esc] or [Spacebar] to return to the "Administrator main menu"