Every port is defined through the following parameters:

Description

Acceptable Value

Default Value

Number

0-8/16/24/32

Same (not changeable)

Name

Up to 15 characters

“Port00” to “Port32”

Type – port 0

User

User (not changeable)

Type – except port 0

User or Host

Host

Baud rate – port 0

300-115200

9600

Baud rate – except port 0

50-128000

9600

Data bits per character – port 0

7,8

8

Data bits per character – except port 0

5,6,7,8

8

Stop bits – port 0

1, 2

1

Stop bits – except port 0

1, 1-1/2, 2

1

Parity

No parity, even, odd

No parity

Handshake mode (flow control)

Xon / Xoff (or in-band, or software),
RTS/CTS (or out-band or hardware),
Both,
None

None

Xon character

any ASCII nonprintable character (0-31 range)

Ctrl+Q (17)

Xoff character

any ASCII nonprintable character (0-31 range)

Ctrl+S (19)

Inter-character delay – except port 0
(no delay allowed on port 0)

1-60 milliseconds, none

None

Line break receive allowance – except port 0
(no allowance for port 0)

Yes or No

No

Transmitted line break extra duration (added
to 1 character transmission time) – except
port 0 (no extra duration for port 0)

No break transmitted, 1-999 milliseconds

No break transmitted

In-band disconnect sequence

0 (disabled), 1, or 3 characters sequence

1-char sequence

1 character disconnect sequence

Any ASCII nonprintable character (0-31 range)

Ctrl+X (24)

3 character disconnect sequence

Any 3 ASCII characters

``` (3 back quotes)

Connection timeout

1-90 minutes, never

15 minutes

DTR output upon disconnect

Low, high, or pulsed for 0.5 seconds and then held
high

High

Modem Reset string

Up to 41 characters

ATZ

Modem Initialization string

Up to 41 characters

AT&F&C1&D2S0=0

Modem Disconnect string

Up to 41 characters

ATH



Appendix B - SERIMUX User and Administrator Characteristics

The users and the administrator are defined through the following parameters:

Description

Acceptable Value

Default Value

Users:
User number

1 to 32

Same (not changeable)

User name

Up to 15 characters – case sensitive

“User01” to “User32”

User password

Up to 31 characters – case sensitive

“” (empty string)

User enabled

Yes or No

Not enabled, except
User 1: enabled

Administrative privileges

Yes or No

No

Access to ports

Port 0 always; Ports 1-31

Port 0, except
User 1: all ports

User menu timeout

1-90 minutes, never

15 minutes

Administrator:
Administrator name

“root” – case sensitive

Same (not changeable)

Administrator password

Up to 31 characters – case sensitive

“nti”

Administrator menu timeout

1-90 minutes, never

15 minutes

User to auto login

User 1-32, None

User 1




Advertising