6 advanced settings – Network Technologies CS-16/8 User Manual

Page 28

Advertising
background image

NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH

23

3.1.6 Advanced Settings

From the "Administrator main menu", press [

7] to display the “Advanced settings” menu.















Figure 18- Administrator's Advanced settings menu


From the "Advanced settings" menu the administrator can perform the following functions:

Setting

Description

Value

Administrator
Password

Define the password to be used by the
administrator

Max. 31 characters.
This can only be changed if old password is known.
(If SERIMUX is re-initialized (pg 30), the default password
(“nti”) will be restored)

Administrator
Timeout

the time interval of administrator
inactivity, prior to logging out.

0-90 minutes 0 = Never

Unit name

Name assigned to the SERIMUX

Max. 40 characters

User to auto login

User assigned to automatically login at
power up without a password.

Index number of any enabled user that has access to the port
being used for the user port

Connect two host
ports

Connect two host ports together

Enter host port index number, press [Enter], second host port
index number, and press [Enter] again

Firmware

Display the firmware menu

See pg. 19

Auto Refresh Period

Refreshes the admin screen after xx
minutes

0-90

Local KeyPad PIN

Defines the PIN number for Local
keypad

4 digit value 0000-9999 (default value is 9999)


FYI: If at power up the auto-login user does not have access to port being used, a login by a valid user with
access rights will be required.

3.1.6.1 Change administrator password

For security purposes the administrator should change the factory default administrator password to a unique password. This will
prevent unauthorized access to switch functions and CPUs. The password is needed to log in from any device, connected to any
SERIMUX port in buffer mode.

To change the administrator password, from the Administrator main menu;

- press [7] to choose Advanced settings and press [Enter]. The Advanced settings menu will appear (Figure 18)
- press [1] and a prompt for the old password will appear
- enter the old password (factory default password is "nti") and press [Enter]
- enter a new password (maximum 31 ASCII characters), using the [Backspace] key to erase any characters entered
in error, and press [

Enter]

- re-enter the password to confirm it, and press [Enter]
- a message "OK" will appear, press any key to return to the Advanced settings menu

Note: The password entered will be case sensitive so be sure to note what characters are used and what case they are in
if any are alphabetical. The password characters are displayed as ‘*’ (asterisk) characters while entering them.

Note:

If the administrator password is not known, the administrator must re-initialize the SERIMUX following the "Reset

SERIMUX Console Switch to default settings" instructions on page 30.