Login a user to the administrator main menu, Login user to a port – Network Technologies CS-16/8 User Manual

Page 39

Advertising
background image

NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH

34


Disconnect the administrator or a user with administrative privileges

Action (from Keypad)

Reaction of SERIMUX

1. Press DISCON

-

The LED “Discon” will illuminate.

-

The port 0 LED will be illuminated, the other port LEDs will be OFF.

2. Press ADMIN

-

The LED "Admin" will illuminate.

3. Press ENTER

-

If command is successful the “Admin”,”Port”,”Discon”.,”User” LEDs will illuminate
together. They will turn OFF after 30 seconds or when any other key is pressed.

-

The message: “Disconnecting administrator now” will be displayed by the terminal
application running on the former administrator port.

Login a user to the administrator main menu


Action (from Keypad)

Reaction of SERIMUX

1. Press ADMIN

-

The LED “Admin” will illuminate. The port 0 LED will be illuminated, the other port LEDs will
be OFF.

2. Press PORT

-

The LED “Port” will illuminate.

3. Enter port number (00 by
default)

-

The corresponding port LED will illuminate, the other port LEDs will be OFF.

4. Press USER

-

The LED “User” will illuminate.

5. Enter user number

-

The corresponding port LED will illuminate

6. Press ENTER

-

If the command is successful the “Admin”,”Port”,”Discon”.,”User” LEDs will illuminate
together. They will turn OFF after 30 seconds or when any other key is pressed.

-

The administrator main menu (Figure 8, page 12) will be displayed on the terminal
application running on the administrator port.


The “Administrator main menu” will be displayed on the serial device connected to the specified port if:
– the administrator is not logged in;
– the specified user has administrative privileges, is enabled, and is not logged in;
– the specified port is accessible to the user;
– the specified port is not otherwise already connected and the port type is “User”.

Login user to a port


Action (from Keypad)

Reaction of SERIMUX

1. Press USER

-

The LED “User” will illuminate.

-

The port 0 LED will be illuminated, the other port LEDs will be OFF.

2. Enter the user number

-

The corresponding port LED will illuminate

3. Press PORT

-

The LED "Port" will illuminate

4. Enter the port number

-

The corresponding port LED will illuminate, the other port LEDs will be OFF.

5. Press ENTER

-

The User main menu will be displayed on the terminal application on the user port: (see
Figure 22 on page 27 )

-

If the command is successful the “Admin”,”Port”,”Discon”.,”User” LEDs will illuminate
together. They will turn OFF after 30 seconds or when any other key is pressed.


The initial user screen will be displayed on the serial device connected to the specified port if:
– the specified user is enabled, and is not logged in at another port;
– the specified port is accessible to the user;
– the port is not otherwise already connected and the port type is “User”.