Specifications

© National Instruments Corporation

A-3

7344/7334 Hardware User Manual

Voltage range .................................. 0 to 5 V

Output low voltage .................. < 0.6 V at 64 mA sink

Output high voltage ................. Open collector with built-in

3.3 k

Ω pull-up to +5 V

Polarity............................................ Programmable, active-high

or active-low

System Safety

Watchdog timer function ....................... Resets board to startup state

Watchdog timeout........................... 63 ms

Shutdown input

Voltage range .................................. 0 to 12 V

Input low voltage ..................... 0.8 V

Input high voltage .................... 2 V

Polarity..................................... Rising edge

Control ............................................ Disable all axes and

command outputs

Motion I/O

Encoder inputs........................................ Quadrature, incremental,

single-ended

Max count rate ................................ 20 MHz

Min pulse width .............................. Programmable; depends

on digital filter settings

Voltage range .................................. 0 to 12 V

Input low voltage ..................... 0.8 V

Input high voltage .................... 2 V

Min index pulse width .................... 60 ns

Forward, reverse, and home inputs

Number of inputs ............................ 12 (3 per axis)

Voltage range .................................. 0 to 12 V

Input low voltage ..................... 0.8 V

Input high voltage .................... 2 V

Polarity............................................ Programmable, active-high

or active-low