Napoleon Fireplaces GDS25P User Manual

Page 10

Advertising
background image

10

W415-0547 / C / 07.25.06

USE GD201 PERISCOPE KIT

BELOW GRADE INSTALLATION

MAXIMUM 10FT VENT LENGTH

OF HORIZONTAL

REGARDLESS

VENT LENGTH

24" MINIMUM

12"MINIMUM

Use the GD201 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
fi nal grading is completed, the bottom air slot is located a
minimum of 12 inches above grade. The maximum allowable
vent length depends on the fi replace, as illustrated.

FIGURES 3 a-c

FIGURE 4

TYPICAL VENT INSTALLATIONS

SPECIAL VENT INSTALLATIONS

40FT

MAX

3FT

MIN

16"

NOTE:

When terminating vertically above 15', the

restrictor plate must be in the fully closed po-

sition. Refer to Restricting Vertical Vents.

PERISCOPE TERMINATION