Vertical termination, 45° v, 90° v – Napoleon Fireplaces GDS25P User Manual

Page 14: 90° h

Advertising
background image

14

W415-0547 / C / 07.25.06

H

1

VERTICAL TERMINATION

0

5

10

15

20

10

20

3

25

30

19

Formula 1: H

T

< 3V

T

Formula 2: H

T

+ V

T

< 40 feet

Example 4:

V

1

= 1 ft

when

(H

T

) > (V

T

)

Simple venting confi gurations
See graph to determine the required vertical rise

V

T

for the

required horizontal run

H

T

.

For vent confi gurations requiring more than one 45º and one
90° elbow , the following formulas apply:

V

2

= 1.5 ft

V

T

=

V

1

+

V

2

= 1 + 1.5 = 2.5 ft

H

1

=

6

ft

H

2

=

2

ft

H

R

=

H

1

+

H

2

= 6 + 2 = 8 ft

H

O

= .03(one 45º elbow + three 90º elbow - 135º)

= .03(45 + 90 + 90 + 90 - 135) = 5.4 ft

H

T

=

H

R

+

H

O

= 8 + 5.4 = 13.4 ft

H

T

+ V

T

= 13.4 + 2.5 = 15.9 ft

Formula 1:

H

T

< 3V

T

3V

T

= 3 x 2.5 = 7.5 ft

13.4 > 7.5

Since this formula is not met, this vent confi guration is
unacceptable.

REQUIRED
VERTICAL
R I S E I N
FEET (V

T

)

HORIZONTAL VENT RUN PLUS OFFSET IN FEET

FIGURE 11

The shaded area within the lines represents acceptable
values for H

T

and V

T

.

90°

FIGURE 12

45°

V

1

90°

V

2

90°

H

2

FIGURE 13

45°

45°

90°

90°

H

1

H

2

90°

H

3

V

2

V

1

Formula 2:

H

T

+ V

T

< 40 feet

15.9 < 40

Since only formula 2 is met, this vent confi guration
is unacceptable and a new fi replace location or vent
confi guration will need to be established to satisfy both
formulas.

Example 5:

V

1

= 1.5 ft

V

2

= 8 ft

V

T

=

V

1

+

V

2

= 1.5 + 8= 9.5 ft

H

1

=

1

ft

H

2

=

1

ft

H

3

=

10.75

ft

H

R

=

H

1

+

H

2

+

H

3

= 1 + 1 + 10.75 = 12.75 ft

H

O

= .03(three 90° elbows + two 45° elbow - 135°)

= .03(90 + 90 + 90 + 45 + 45 - 135) = 6.75 ft

H

T

=

H

R

+

H

O

= 12.75 + 6.75 = 19.5 ft

H

T

+ V

T

= 19.5 + 9.5= 29 ft

Formula 1:

H

T

< 3V

T

3V

T

= 3 x 9.5 = 28.5 ft

19.5 <

28.5

Formula 2:

H

T

+ V

T

< 40 feet

29

<

40

Since both formulas are met, this vent confi guration is
acceptable.

Advertising