Location & clearances, 7" dia. 23, 4" dia – Napoleon Fireplaces GDS25P User Manual

Page 6: Stove dimensions

Advertising
background image

6

W415-0547 / C / 07.25.06

MAINTAIN THESE MINIMUM CLEARANCES

TO COMBUSTIBLES:

A. 4"

B. 2"

*

C. 2"

STOVE

SHOULD

NOT

BE

INSTALLED

DIRECTLY

ON

CARPETING

.

TO

CEILING

FROM

STOVE

TOP

..................................................48"

HORIZONTAL VENT

SIDES

AND

BOTTOM

................................................................1"

TOP

......................................................................................2"

VERTICAL VENT

ALL

SIDES

.............. ...............................................................1"

*

AT

A

DISTANCE

OF

2"

FROM

THE

WALL

,

INSTALLATION

OR

SERVICE

TO

THE

BLOWER

MAY

NOT

BE

PRACTICAL

.

A

MINIMUM

OF

5"

WILL

BE

REQUIRED

IN

ORDER

TO

INSTALL

THE

BLOWER

.

If less than 5" clearance is maintained between the back
of the stove and the back wall, it will be necessary to
disconnect the venting and gas pipe to move the stove
out for installation or service of the blower.

Provide adequate accessibility clearance for

servicing and operating the stove.

Never obstruct the front opening of the stove.

FIGURE 2

LOCATION & CLEARANCES

STOVE DIMENSIONS

FIGURE 1

7" DIA.

23

1

/

2

"

12

3

/

4

"

23

5

/

8

"

25

5

/

8

"

17

1

/

2

"

4" DIA.

As long as clearance to combustibles is kept within the re-
quired distances, the most desirable and benefi cial location
for a Napoleon stove is in the centre of a building, thereby
allowing the most effi cient use of the heat created. The loca-
tion of windows, doors and the traffi c fl ow in the room where
the stove is to be located should be considered. If possible,
you should choose a location where the vent will pass through
the house without cutting a fl oor or roof joist.

8”

MIN.

12”

MAX. MANTEL WIDTH

COMBUSTIBLE

MATERIALS

COMBUSTIBLE
MANTEL OR TRIM
MATERIAL

2”

When the
fi replace is rear
vented, a mantel
or shelf may be
installed above
the GDS25 at a
minimum
distance of 8".

MANTEL OR SHELF CLEARANCES:

Advertising
This manual is related to the following products: