Wall and ceiling protection, Vent pipe shield vent pipe collar o, Horizontal installation – Napoleon Fireplaces GDS25P User Manual

Page 16: Vertical installation

Advertising
background image

16

W415-0547 / C / 07.25.06

This application occurs when venting through an exterior wall.
Having determined the air terminal location, cut and frame
a hole in an exterior wall with a minimum rectangle opening
of 10" x 9".
IMPORTANT: FOR OPTIMUM PERFORMANCE, THE
STOVE PIPE SHOULD RISE ¼" PER FOOT OF RUN.

1. Assemble the shield to the spacer as shown, using the

3 shorter screws supplied.

The shield is meant to protect combustible materials within

the wall. If the shield is deeper than the combustible portion
of the wall, cut to fi t.

2. Apply a bead of caulking all around and place the fi restop

spacer over the framework to restrict cold air from being drawn
into the room or around the stove. Ensure that both spacer
and shield maintain the required clearance to combustibles.
Secure the spacer in place using the 4 longer screws sup-
plied. Once the vent pipe is installed in its fi nal position, apply
sealant between the pipe and the fi restop spacer.

FIGURE 16

HORIZONTAL INSTALLATION

This application occurs
when venting through a
roof.

Installation kits for vari-
ous roof pitches are
available from your Na-
poleon dealer. See Ac-
cessories to order the
specifi c kit required.

1. Determine the air terminal location and move the stove into
position. Cut and frame 9" x 10" openings in the ceiling and
the roof to provide the minimum 1 inch clearance between
the stove pipe and any combustible material. Try to center the
exhaust pipe location midway between two joist to prevent
having to cut them. Use a plumb bob to line up the center of
the openings.

DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL.

A vent pipe shield will
prevent any materials
such as insulation, from
fi lling up the 1" air space
around the pipe. Nail
headers between the
joist for extra support.

2. Apply a bead of

caulking (not supplied) to the framework or to the Wolf Steel
vent pipe shield plate or equivalent (in the case of a fi nished
ceiling), and secure over the opening in the ceiling. A fi restop
must be placed on the bottom of each framed opening in a
roof or ceiling that the venting system passes through. Apply
a bead of caulking all around and place a fi restop spacer over
the vent shield to restrict cold air from being drawn into the
room or around the stove. Ensure that both spacer and shield
maintain the required clearance to combustibles. Once the
vent pipe is installed in its fi nal position, apply sealant between
the pipe and the fi restop spacer.

3. In the attic, after the pipe has been installed, slide the

vent pipe collar down to cover
up the open end of the shield
and tighten. This will prevent any
materials, such as insulation,
from fi lling up the 1" air space
around the pipe.

FOR SAFE AND PROPER

OPERATION OF THE STOVE,

FIGURE 18

VENT PIPE

SHIELD

VENT

PIPE

COLLAR

O

FIGURE 19

VERTICAL INSTALLATION

WALL AND CEILING PROTECTION

9

9"

"

1

10

0"

"

U

UN

ND

DE

ER

RS

SIID

DE

E O

OF

F J

JO

OIIS

ST

T

F

FIIR

RE

ES

ST

TO

OP

P

FIGURE 17

Advertising