Horizontal termination, 90° h, 45º 90 – Napoleon Fireplaces GDS25P User Manual

Page 11: Elbow vent length values definitions

Advertising
background image

11

W415-0547 / C / 07.25.06

ELBOW VENT LENGTH VALUES

DEFINITIONS

HORIZONTAL TERMINATION

0

2.5

5

7.5

10

12.5

15

40

10

20

30

17.5

20

39

REQUIRED
VERTICAL
R I S E I N
FEET (V

T

)

CALCULATED HORIZONTAL VENT RUN
PLUS OFFSETS IN FEET (H

T

)

FIGURE 5

45º

FIGURE 6

90°

H

1

H

2

when

(H

T

) < (V

T

)

for the following symbols used in the venting calculations
and examples are:

> - greater than

> - equal to or greater than

< - less than

< - equal to or less than

H

T

- total of both horizontal vent lengths (

H

R

) and offsets

(

H

O

) in feet

H

R

- combined horizontal vent lengths in feet

H

O

- offset factor: .03(total degrees of offset - 135°

*) in

feet

V

T

- combined vertical vent lengths in feet

feet

inches

0.03

0.5

15°

0.45

6.0

30°

0.9

11.0

45°

*

1.35

16.0

90°

*

2.7

32.0

* the fi rst 45º and 90° offset has a zero value and is
shown in the formula as -45° and -90º respectively or
-135º when combined.

For vent confi gurations requiring more than one 45º and 90°
elbow, the following formulas apply:

Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 40 feet

Example 1:

V

1

= 8

ft

V

T

=

V

1

= 8 ft

H

1

= 2.5

ft

H

2

= 2

ft

H

R

=

H

1

+

H

2

= 2.5 + 2 = 4.5 ft

H

O

= .03(one 45º elbow + two 90º elbows - 135º)

=0.3(225-135º) = 2.7ft

H

T

=

H

R

+

H

O

= 4.5 + 2.7 = 7.2 ft

H

T

+ V

T

= 7.2 +8 =15.2ft

Formula 1:

H

T

< V

T

7.2 < 8

Formula 2:

H

T

+ V

T

< 40 feet

15.2 < 40

45º

90°

Since both formulas are met, this vent confi guration is
acceptable.

V

1

90°

The shaded area within the lines represents acceptable
values for H

T

and V

T

.

Simple venting confi guration (only one 45º and 90° elbow)