Optional switch / wiring diagram – Napoleon Fireplaces GDS25P User Manual

Page 21

Advertising
background image

21

W415-0547 / C / 07.25.06

OPTIONAL SWITCH / WIRING DIAGRAM

The on/off switch is located on the back of the
GDS25 at the top right corner. For ease of acces-
sibility, an optional remote wall switch or millivolt
thermostat may be installed in a convenient location.
The recommended maximum lead length depends on
wire size:

WIRE SIZE

MAX. LENGTH

14

gauge

100

feet

16 gauge

60 feet

18 gauge

40 feet

Route 2-strand (solid core) wire through the electri-
cal hole located at the bottom left side of the unit.
Connect the wires from the wall switch / thermostat
to the two brown wires extending from the fi replace
mounted ignition control box.

Purge all gas lines with the glass door of the fi replace open.

Assure that a continuous gas fl ow is at the burner before closing the door.

B

URNER

S

WITCH

/ W

ALL

T

HERMOSTAT

B

ATTERY

H

OLDER

G

AS

V

ALVE

P

ILOT

A

SSEMBLY

I

GNITION

M

ODULE

P

ILOT

G

AS

L

INE

Orange
(I)

[through

independent

conduit]

Yellow
(S)

[through
Gas line

conduit]

AC A

DAPTOR

B

ATTERY

R

ELAY

Red (3 Volt)

Red

Black

W

IRE

H

ARNESS

N

OTE

: W

IRE TAGS

ARE BRACKETED

Brown
(SWI)

Black
(-)

Red
(+)

Green x2
(TH)

Orange x2
(THTP)

Black

Yellow

Blue

Black
(TP)

M

ODULE

P

LUG

R

ELAY

P

LUG

Black

Green

Orange

Black (12 Volt)
To Accent Light &
Accent Light Switch

Advertising
This manual is related to the following products: