Winter humidity levels are too low
1. If you have installed a dehumidistat ensure that its setting

is correct. (Summer - OFF) (Winter - 30% RH to 45%
RH).

2. Check humidifier settings. (Summer - OFF) (Winter -

30% RH to 45% RH).
NOTE: Humidifier should always be 10% lower than
dehumidistat.

3. Change thermostat fan switch from manual to automatic.

Summer humidity levels are too high
1. If you have installed a dehumidistat ensure its setting is

correct. (Summer - OFF)(Winter - 30% RH to 45% RH).

2. Change thermostat fan switch from automatic to manual.

NOTE: The CAF has the ability to dehumidify during the
heating season. (When outside air is less humid than
indoor air). If you are in a region where outdoor humidity
levels are typically higher than indoor humidity levels, a
dehumidistat should not be used in this system.

Troubleshooting

Winter Setting
30% to 45%

Summer Setting
“OFF”

Optional Dehumidistat
This control will reduce winter humidity levels when outdoor
air approaches or exceeds freezing.