Dimensions & clearances – Lifebreath Clean Air Furnace CAF-02-MB User Manual

Page 35

Advertising
background image

35

Options
99-186

Weatherhoods, Two - 6" (150 mm)
c/w 1/4" (6 mm) mesh screen

99-130W

Remote Wall Mount Dehumidistat Control 24
VAC only

99-RSK6

6” (150 mm) back draft damper

99-104

DET - Digital Electronic Timer

Top

Front

29.5"

(749 mm)

47.5"
(1207 mm)

6"

(150 mm)

14"

(356 mm)

12"

(305 mm)

4"

(100 mm)

19"

(483 mm)

22.25"

(565 mm)

Supply Air

17.25"

(438 mm)

Ventilation Supply
Air Inlet

Ventilation Exhaust
Air Outlet

22"

(559 mm)

Return Air

Latches

Blower Section

Side

(SERVICE CLEARANCE 1')

(SERVICE CLEARANCE 3')

29.5"

(749 mm)

19"

(483 mm)

6"

(150 mm)

Dimensions & Clearances

Core

Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy recovery core (optional) for
energy-efficient ventilation. Enthalpic cores are recommended for regions where the temperature does not drop below 25°F
(-4°C).

Filters

Washable air filters in exhaust and supply air streams of ventilation section, 1" (25 mm) pleated in return plenum side

Case

Prepainted galvanized steel for superior corrosion resistance.

Note: Ventilation ports and return plenum

opening available off either side of cabinet.

All units conform to CSA and UL Standards.

Model

CAF-U-L2A-48-P16

Voltage

120 VAC 60 Hz

Hp

1/2

Amps (total)

10.6

Water

1/2" (12 mm) Copper

Connections

Soldered Connection

Airflow (High)
.25 in wg

1888 CFM

.5 in. wg

1589 CFM

Ventilation

100 - 140 CFM

Airflow

Effectiveness

70%

(Aluminum Core)

Total Efficiency

50%

(Enthalpic Core)

Net Weight

150 lbs.

Shipping Weight

165 lbs.

Warranty
Units carry a lifetime warranty on the heat recovery (alu-
minum) core, a five year warranty on the energy recovery
(enthalpic) core and a five year replacement parts warranty
on all other components.

Date: ___________________________________________

Tag: _____________________Qty:___________________

Project: _________________________________________

Engineer: _______________________________________

Contractor: ______________________________________

Supplier: ________________________________________

Quote#: _________________________________________

Submitted by: ____________________________________

Model CAF-U-L2A-48-P16

Advertising