Plumbing

In order to improve serviceability of our products, the
check valve is included with our manual kit for field instal-
lation between the air-handler and hot water source.

The check valve should be installed in a vertical run of
pipe with the flow of water in an upward direction.

An arrow on the check valve indicates its correct orienta-
tion and must match the direction of water flow.

This will allow for ease of service to remove any installa-
tion debris or service required due to extended hard water
conditions.

Note: Take care during soldering to avoid debris or

solder from lodging in the check valve.

Note: It is critical to follow the piping configuration

shown. Maintain a minimum distance of 12” above

the CAF/AH. This will minimize thermal siphoning in

the combo system.

* It should be noted that problems have been observed when using the side

tappings on certain water heaters; therefore, it is strongly recommended to use the top

water tappings as indicated in Figure 1 to minimize thermal siphoning and related

issues.