Resampling vibration data, Resampling vibration data -4 – National Instruments Order Analysis Toolset User Manual

Page 44

Advertising
background image

Chapter 4

Resampling-Based Order Analysis

LabVIEW Order Analysis Toolset User Manual

4-4

ni.com

Figure 4-2. Original Time Sequence and CIC Interpolation Filter with

an Interpolation Factor of Eight

Resampling Vibration Data

The resampling operation converts a vibration signal from the time domain
into the angle domain. To resample vibration data into even angle spaced
samples, you must be able to calculate the value of the vibration signal at
any time instance.

According to the Nyquist sampling theorem, you can exactly reconstruct
the signal for all time instances using band-limited interpolation if and only
if the original signal is band limited to half of the sampling rate.

For example, a continuous time signal x(t) that is band limited to f

s

/2 Hz and

sampled at a sampling rate of f

s

samples/second yields a discrete sample

given by the following equation.

x

n

= x(nT

s

),

where T

s

= 1/f

s

and is the sampling time interval.