AutoCode Sim Cdelay Scheduler

© National Instruments Corporation

8-11

AutoCode Reference

Figure 8-6. New STD for ATR Triggered Tasks

Figure 8-7. New STD for ATR Triggered Tasks

IDLE

RUNNING

BLOCKED

task

done

Timer is zero and

enable, reset timer

and post outputs

Timer is zero and

!enable, reset

timer and post

outputs

Timer greater

than zero,

decrement it

Timer has reached

zero, signal overflow

Timer greater

than zero,

decrement it

Timer is zero and

!enable, reset timer

Timer is zero and

enable, reset timer

IDLE

RUNNING

BLOCKED

task

done

Timer greater

than zero and

!trigger, decrement

timer

Timer is zero and

!trigger, post

outputs

Timer is zero and

trigger, reset timer

and post outputs

Timer greater than

zero and trigger,

reset timer

Trigger,

reset timer

Timer is zero

or trigger,

signal overflow

Advertising