Config network javamode, Config prompt, Show serial – NETGEAR 7200 Series Layer 2 Managed Switch Software User Manual

Page 57: Config network javamode -15, Config prompt -15, Show serial -15

Advertising
background image

User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software

Switching Commands

7-15

202-10010-01

Default

enable

Format

config network webmode <enable|disable>

config network javamode

This command specifies whether or not the switch should allow access to the Java applet in the
header frame of the Web interface. When access is enabled, the Java applet can be viewed from the
Web interface. When access is disabled, the user cannot view the Java applet.

Default

enable

Format

config network javamode <enable|disable>

config prompt

This command changes the name of the prompt. The length of name may be up to 64 alphanumeric
characters.

Default

<model #>

Format

config prompt <system prompt>

show serial

This command displays serial communication settings for the switch.

Format

show serial

Serial Port Login Timeout

(minutes)

Specifies the time, in minutes, of inactivity on a Serial port connection, after
which the Switch will close the connection. Any numeric value between 0 and
160 is allowed, the factory default is 5. A value of 0 disables the timeout.

Baud Rate

The default baud rate at which the serial port will try to connect. This is selected
from a pull-down menu. The available values are 1200, 2400, 4800, 9600,
19200, 38400,57600, and 115200 baud. The factory Default is 9600 baud.

Character Size

The number of bits in a character. The number of bits is always 8.

Flow Control

Whether Hardware Flow-Control is enabled or disabled. Hardware Flow
Control is always disabled.

Stop Bits

The number of Stop bits per character. The number of Stop bits is always 1.

Parity Type

The Parity Method used on the Serial Port. The Parity Method is always None.