System trouble error codes – Napco Security Technologies F-TPG User Manual

Page 18

Advertising
background image

18

SYSTEM TROUBLE ERROR CODES

TBL

Flashes /

Touchpad beeps

READY

Flashes

Trouble Condition

Action

6

NONE Lost Key Mode

This is a reminder that the system has been put into the lost key mode ([STAY] &
[AWAY] pressed simultaneously). While in this mode, the system can only be
disarmed with your F-IFOB. When you have replaced or re-keyed your garage
door opener, press [STAY] & [AWAY] simultaneously again to exit lost key mode.

7

NONE Fire Zone Trouble

A problem has been detected with the Fire zone. Call for service.

1 1

Wireless

Receiver

TBL

or Touchpad TBL

A problem has been detected with the wireless receiver. Call for service.

2

2

Wireless Receiver Jam A problem has been detected with a wireless receiver. Call for service.

3 1-8

Wireless

Transmitter

Low Battery

The battery in a wireless transmitter is low and should be replaced. This transmit-
ter is on the zone corresponding to the number of

READY

flashes. The replace-

ment battery for the GEM-TRANS2 door/window transmitter, GEM-PIR motion
detector and GEM-GB glass break detector is the Duracell DL123A 3 Volt Lithium
(2 required for the GEM-PIR and GEM-GB). The GEM-DT Dual Technology Sen-
sor requires 4 C cell Alkaline batteries.

Warning: Replace batteries only with the same

type as specified above. Use of another battery may present a risk of fire or explosion. Do
not recharge or disassemble battery, or dispose of in fire.

4 1-8

Wireless

Transmitter

Supervisory Failure

A problem has been detected with a wireless transmitter on the zone correspond-
ing to the number of

READY

flashes. Call for service.

5

1-4

Wireless Smoke
Detector Low Battery

The battery in a wireless smoke detector is low and should be replaced. The
number of the smoke detector corresponds to the number

READY

flashes. The

replacement battery is the Duracell MN1604 9 Volt Alkaline (2 required).

Warning: Replace batteries only with the same type as specified above. Use of another
battery may present a risk of fire or explosion. Do not recharge, disassemble, or dispose of
battery in a fire.

6

1-4

Wireless Smoke
Detector Supervisory
Failure

A problem has been detected with a wireless smoke detector. Call for service.

F-TPG_OI309.06_USER_anch...

page 18

Friday, October 28, 2005 15:16

Composite

Advertising