The F-IFOB is a uniquely coded digital key which performs the following functions when inserted into the F-IFOB slot on the Ga-
rage Touchpad:

Disarm an armed system

Silence an active alarm

Reset a fire alarm

The Master F-IFOB supplied with your system will perform all of these functions, plus it may also be used to add up to 5 addi-
tional F-IFOBs to the system. The following instructions will guide you through adding additional F-IFOBs as well as removing
F-IFOBs in the event that one is lost.

Adding additional IFOBs to your system:

1. With the system disarmed, insert the Master F-IFOB into the F-IFOB slot on the Garage Touchpad.
2. Wait for beep and then remove the Master F-IFOB.
3. Within 8 seconds insert the new F-IFOB into the F-IFOB slot on the Garage Touchpad.
4. Wait for 5 beeps and remove the new F-IFOB.
5. Test the new F-IFOB by arming the system in the STAY mode and using the F-IFOB to disarm

the system.

Repeat the above steps for each F-IFOB to be enrolled.

Removing IFOBs from the system:

In the event that an F-IFOB is lost, the following procedure must be used to remove all of the F-IFOBs
except the Master:

On a disarmed system:
1. Insert the Master F-IFOB, until beep.
2. Hold Down the SILENCE button for 4 seconds, until beep.

Re-Enroll the F-IFOBs using the procedure above.

In the event that the Master F-IFOB is lost, contact the alarm company to arrange a replacement.