Specifications

This section lists the specifications of the TB-2708. These specifications
are typical at 25 °C unless otherwise specified.

Input/Output

Refer to the documentation for your PXI-6115/6120 S Series device to
determine the input/output specifications for your application.

Caution

Do not apply an input voltage greater than 42 V

pk

/60 VDC to the TB-2708. Input

voltages greater than 42 V

pk

/60 VDC can damage the TB-2708 and any device connected

to it, including the host computer. Overvoltage can also cause an electric shock hazard for
the operator. National Instruments is not liable for damage or injury resulting from such
misuse.

Physical

Dimensions

Height.............................................. 10.7

Ч 8.6 Ч 2.0 cm

(4.2

Ч 3.4 Ч 0.8 in.)

Weight............................................. 144.6 g (5.1 oz)

I/O connectors

68-position SCSI-II type ................. 1, female

SMB jacks....................................... 9

14-pin auxiliary connector .............. 1, Molex 14-pin microfit

connector

Shock and Vibration

Operational shock .................................. 30 g peak, half-sine, 11 ms pulse

(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)

Random vibration

Operating ........................................ 5 to 500 Hz, 0.3 g

rms

Nonoperating .................................. 5 to 500 Hz, 2.4 g

rms

(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds
the requirements of
MIL-PRF-28800F, Class 3.)