System times, System features – Napco Security Technologies XP-400 User Manual

Page 13

Advertising
background image

13

[08]PGM Output

Enables the PGM Output on a zone trip for
each zone selected. The PGM Output will
remain ON until reset.

System Times

[10]Exit Delay

The delay time which permits exit through
an Exit/Entry Zone [00] after the system is
armed, allows a user to leave the premises
without setting off an immediate alarm. Exit
Delay
may be programmed for up to 255
seconds (4¼ minutes); a value of 0 defaults
to 60 seconds.

[11]Entry Delay

Delay time permits entry through Exit/Entry
Zone(s)
after the system is armed without
setting off an immediate alarm. Entry Delay
allows the user time to enter and disarm the
system. Upon entering, the keypad sounder
will sound a steady tone (Entry Sound) to
remind the user to disarm the system.
Entry Delay Time [11] may be programmed
for up to 255 seconds (4¼ minutes); a value
of 0 defaults to 30 seconds. Entry Delay

may be canceled by pressing

a4

before

or after arming.


[12]Burg (Steady) Output Time-out

Can be programmed from 1 to 255 min (4¼
hours); 0 means output will stay ON until
turned off by entering an Arm/Disarm Code.


[13]Reserved

[14]Test Timer Interval

Program the interval, in days, between Test
Timer reports. Test Timer Interval may be
programmed from 1 to 255 days.


[15]Line Cut Time-to-Fail

Enable this feature by programming the
delay time required to declare a line cut
failure. Programming 000 will disable line
cut detection.


[16]Wireless Supervisory Timer

A transmitter will send a transmission every
time it is tripped; when there is no activity,
the transmitter sends a supervisory
transmission about once an hour. If the
receiver does not receive any signal (either

a trip or a status) from a transmitter in the
time specified, a system trouble ‘RF
Supervisory Failure' will be indicated at the
keypad. Timer is programmable from 1-26
hours; 0 means NO supervision.

System Features

[20]Keypad Features 1

(1) Enable Keypad Panic 2 (

KK

)

Additional Programming required:
Select reporting to Telco 1 [36-1] or Telco 3
[56-1].
(2) Enable Keypad AUX (

ff

)

Additional Programming required:
Select reporting to Telco 1 [36-2] or Telco 3
[56-2].
(3) Enable Keypad Panic (

gG

)

Additional Programming required:
Select reporting to Telco 1 [36-3] or Telco 3
[56-3].
(4) Enable Ambush - If enabled, the 4th
User Code will send an Ambush report when
entered to disarm the system. Additional
Programming required: Program User 4 Arm/
Disarm Code. Select reporting to Telco 1 [36-
2] or Telco 3 [56-2].