Bypassing – Napco Security Technologies XP-400 User Manual

Page 8

Advertising
background image

8

WI1370 XP-400 Installation Instructions

Arming/Disarming with a Keyfob

The system can be armed by pressing the

K

key, and disarmed by pressing the

L

key on

the Keyfob. Zones programmed as Exit/Entry
Follower Zones
can be bypassed when the

M

or

N

keys on the Keyfob have been

programmed for Interior [81-82]. Zones
programmed as Home/Away with Delay Zones
can be armed regardless of the state of the Exit/
Entry Zones
when the

M

or

N

keys on the

Keyfob have been programmed for Full Set [81-
82]. To arm the system with all zones protected,
press the

K

key. Press and hold the

M

or

N

key for 1.5s to fully set the system (The

LED on the Keyfob indicates the Keyfob is
tranmitting the signal). Program Keyfob/
Keyswitch Chirp
[23-4] for an audible indication
of system arming and disarming.

Arming Instant with a Keyfob

The panel can be ARMED INSTANT when the

M

or

N

keys on the Keyfob have been

programmed for Instant [81-82]. To arm the
system with Instant protection press the

K

key, then press and hold the

M

or

N

key for

1.5s to arm the panel with INSTANT protection.

Arming/Disarming with a Keyswitch

The system can be armed/disarmed by using a
momentary Keyswitch wired to Zone 4. Program
Keyfob/Keyswitch Chirp
[23-4] for an audible
indication of system arming and disarming.




Disarming (System OFF)

After entering the premises through an Exit/
Entry Zone, the keypad will sound the Entry
Delay Tone. Enter a valid Arm/Disarm code. If
a valid Arm/Disarm code is entered, the keypad
will beep 6 times, indicating the panel has been
disarmed. The red Armed LED will go out. If an
incorrect Arm/Disarm Code is entered, the
keypad will sound a 1-second tone, indicating
incorrect entry. Press the

B

key and re-enter

the code.

Disarming after an Alarm

(Alarm Memory)

The armed LED and the zone(s) that caused the
alarm will be be flashing. Disarm the panel.
The system is currently not detecting zone faults
or displaying system trouble. The zone(s) that
caused the alarm will continue to flash. The

Ready and

H

SYSTEM TRBL LEDs are out

indicating:

The system is displaying Alarm Memory.

Press the

B

key to clear Alarm Memory.

Bypassing


Automatic Bypassing
Home/Away with Delay Zones

This zone type has the following operation
depending on whether an Exit/Entry Zone has
been violated during the Exit Delay time.

Home

Exit/Entry Zone is not violated
Zones selected as Home/Away with Delay
Zones
will be bypassed automatically.


Away with Delay

Exit/Entry Zone is violated
Zones selected as Home/Away with Delay
Zones
will have a fixed 20-second entry
delay when violated before an Exit/Entry
Zone
.

N

OTE

:

Faulted Keyswitch or silent 24 hour zones normally do not
display at the keypad. If a silent 24 hour zone or
Keyswitch is faulted at the time of arming the faulted zone
will display only while the priority sound is ON.

Advertising