Programming the panel – Napco Security Technologies XP-400 User Manual

Page 5

Advertising
background image

5

Programming the Panel

Refer to XP-400 Programming Instructions (WI1371)

Defaulting the Panel

1. Remove power from the panel.
2. Remove all wiring from terminal 15 (PGM)

and terminal 3.

3. Connect terminal 15 (PGM) to terminal 3.
4. Apply power to the XP-400 control panel.
5. After a few seconds the

W

ARMED,

X

READY and

H

SYSTEM TROUBLE LEDs

will flash.

6. The keypad will beep 3 times indicating the

panel default values have been loaded.

7. Remove wiring between terminal 15 (PGM)

and terminal 3.

8. Re-install original wiring for terminal 15

(PGM) and terminal 3.






Keypad Programming

Refer to WI1371 for information on keypad
programming.

Downloading

The XP-400 panel can be download/uploaded
with PCD3000 software using the Ring Method,
Answering Machine Override (Second Call) or

A6

Method of downloading. The panel can

also be automatically downloaded/uploaded
using PCD2000 Software running PCPreset.
For Site Initiated Downloaded, see Auto
Download ID Number
[93].

Local Downloading

Wire as shown in Figure 1. Use the power up or

A6

method of establishing a connection. The

power up method is recommended if the panel is
attempting to report.










Remote Downloading

Wire as shown in Figure 2. The panel can be
remotely download/uploaded using any one of
the following methods:

1. The

A6

method

2. Call-in method
3. Answering Machine Override (Second Call)

4. Site-Initiated (PCPreset &

A6

)

5. Automatic Downloading (Using PCPreset)

MODEM

J1

TO COMPUTER

J3

LOCAL

TO

PCI2000

J2

TO EXTERNAL

MODEM

J4

TELCO

J5 LINE
OUT TO

TELCO

FIGURE

2 R

EMOTE

D

OWNLOAD

PGM

(-)

+12

-13 14 15

16 17 18 19

+PWR

GND GREEN

PHONE

TELCO

GREEN

RED

XP-400 Panel at the site

RING

TIP

RING

RJ31X

TIP

GRY

BRN

PGM

(-)

+12

-13 14 15

16 17 18 19

+PWR

GND GREEN

TIP

RING

PHONE

PCL2000A

GREEN

RED

MODEM

FIGURE

1 L

OCAL

D

OWNLOAD

TIP

RING

TELCO

BLACK

RED

N

OTE

:

Any programming in Dealer Options 1 [96] and Dealer Options
2
[97] will not be defaulted. If Dealer Code Lockout has been
programmed the panel will not default the Dealer Code.

Advertising