Specifications – Napco Security Technologies XP-400 User Manual

Page 3

Advertising
background image

3

Specifications


Current & Voltage Ratings

Alarm Output -------------------------- Burg: 12 VDC, 2A (max.)

Output Current Limiting -------------- Burg: 2.25 A

AUX Power: 750 mA


Residential Burglary (4 Hour Standby)
Combined Standby Current: -------- 350 mA
Bell Output: ---------------------------- 2 A
(Using Rechargeable 12 VDC 4 AH BATTERY, minimal requirement)

Transformer and Battery

Required Transformer: -------------- NAPCO TRF12 OR
BASLER 16.5 VAC 20VA

Required Battery: --------------------- 12V 4 AH Rechargeable
Change Battery every 5 years or as required

Maximum Charging Current: ------ 165 mA

Maximum Input Current: ------------- 2.58 A



Loop Characteristics

Loop Voltage: --------------------------5 Volts

Loop Current : --------------------------Zones 1, 2: 0.9 mA (2.2 K)

Zones 3, 4: 0.5 mA (3.9 K)


Loop Resistance: ----------------------100

per zone (max.)


Device Specifications

Max # keypads: ------------------------4, RPXP4GT current = 35 mA


Max # of receivers: --------------------2, GEM-RECV-XP8

current = 65 mA each



Max Keypad wire length : ----------1000’ total wire length

Miscellaneous


Housing Dimensions : --------------10

5

/

16

"

x 8

6

/

16

"

x 3"

(26.2 x 21.3 x 7.6) HxWxD

Shipping Weight: ---------------------XP-400/4 15.5 lbs.

Operating Temperature: -------------0-49ºC (32-120°F)