System troubles, Viewing system trouble(s) – Napco Security Technologies XP-400 User Manual

Page 23

Advertising
background image

23

System Troubles

Use the System Trouble chart on the following
page to determine the specific System Trouble
(s).

During normal panel operation the

HSYSTEM

LED has the following two modes of operation:

STEADY 1-7 possible trouble

groups, AC is present

FLASHING 1-7 possible trouble

groups, AC is not present

Viewing System Trouble(s)

Press the

I

key on the keypad. To determine

the System Trouble Group Number, count the
number of times the

HSYSTEM LED blinks.

The keypad sounder will beep at the same rate
that the

HSYSTEM LED blinks.

To determine the System Trouble, note the
zone LED that is ON. Look up the specific
system trouble on the chart on the following
page.

The

HSYSTEM LED and keypad sounder will

continue to flash and beep. To view the next
System Trouble, if any, press the

C

key.

Continue pressing the

C

key, if there are no

more system troubles to view, the system will

return to normal operation.




























Note: System Troubles Groups 3 through 7 -
System Trouble Groups that have a zone or
smoke detector associated with the trouble,
such as RF low battery. The zone(s) of the
device with a low battery will be displayed by the

ZONE LED. For example, a wireless low battery
on zone 2 would beep the keypad sounder 3
times and turn on zone 2 LED.

Audible System Trouble Indication - For all
system troubles, except when the only system
trouble is the loss of AC, the keypad will beep
once every 10 seconds. The keypad will
continue to beep until the reset button is pressed
or the trouble has been acknowledged by
pressing the

i

key.

System Trouble Reporting

The following system troubles, when enabled to
report to Telco 1 [37-3] or Telco 3 [57-3], will
send the report code programmed in Trouble
Report [63] if reporting using a pulse format:

System Trouble Pulse Report Code

Bell Cut F1
2-Wire Fire Trouble F1
Rcvr Fail-to-Respond F1
Receiver Tamper F1
Receiver JAM F1
Tx Low Battery F1
Tx Supervisory Failure F1

If reporting using Point ID, a unique code will be
sent for each of the following System Troubles.

System Trouble Point ID Report Codes

Bell Cut CODE 1 321 G00 ZN000-BELL 1 TROUBLE
2-Wire Fire Trouble CODE 1 373 G00 ZN000-FIRE LOOP TRBLE
Rcvr Fail-to-Respond CODE 1 382 G00 ZN000-SENSOR TROUBLE
Receiver Tamper CODE 1 145 G00 ZN000-EXP. MODL. TAMPER
Receiver JAM CODE 1 373 G00 ZN000-FIRE LOOP TRBLE


A 300 (SYSTEM TROUBLE RST) code is sent if a restore is
reported after multiple troubles.

System Trouble

Group #

Keypad

H

SYSTEM

Trouble LED is flashing 1
time, indicating System
Trouble Group 1.

Keypad Sounder beeps 1
time indicating System
Trouble Group 1.

EXAMPLE

-

LOW

BATTERY

SYSTEM

TROUBLE

Zone LED(s)

is ON

indicates
(Specific Trouble)

Specific Trouble


Zone 2 LED is ON indicating
Low Battery. (1 Beep, LED 2)

Flashing

(System
Trouble
Group
Number)

Press the

i

to enter System Trouble mode and

determine the specific trouble. Press any key to
view all system troubles.

Beeping

(System
Trouble
Group
Number)

FIGURE

8 S

YSTEM

T

ROUBLE

E

XAMPLE

Advertising