Nortel Networks NN46200-310 User Manual

Page 33

Advertising
background image

Installing the DC power supply

33

5

Push the new power supply partway into the bay, leaving the
terminal block at the side of the power supply exposed.
See

“Job aid: Inserting the DC power supply” (page 36)

.

6

Use a Phillips screwdriver to remove the screw that secures the
plastic safety cover to the power supply and remove the cover.
Set the cover aside; you will replace it later.

7

Note the positions of the ground studs and of the positive and
negative power inputs. See

“Job aid: DC power supply input and

ground stud location” (page 36)

.

Either +VDC or –VDC can be referenced to the frame ground for
+48 VDC (nominal) or –48 VDC (nominal) applications.

8

Make sure that the +DC cable is always connected to the
positive terminal and the –DC cable is always connected to the
negative terminal.

DANGER

Risk of injury by electric shock

Before you continue with this procedure, ensure that
the DC power source is switched off.

9

Attach the earth ground lead to the ground stud on the power
supply. See

“Job aid: Attaching the earth ground lead to the

ground stud” (page 37)

.

Use the washers in the following order:

a

flat washer

b crimp lug

c

lock washer

d Hex nut

Nortel Ethernet Routing Switch 8300

Installation — DC Power Supply

NN46200-310

01.01

Standard

9 June 2008

Copyright © 2008 Nortel Networks

.