Burner Adjustment

41

5. Slowly open the air band until white smoke just starts to appear.

6. Turn air band halfway back to the black smoke position previously noted.

Tighten the locking screw.

7. Now fine tune the burner air by adjusting the shutter:

a. Locate the shutter as shown in Figure 14 below. The shutter is a thin

circular metal plate located on the outside of the air band. The shutter
adjusts independently from the air band and is used to fine-tune the
amount of intake air.

b. Observe that the aluminum pointer attached to the shutter. It points to the

same set of calibration numbers as the air band arrow. Observe which
number it points to at the start of this adjustment step.

c. Loosen the shutter lock screw. Turn the shutter using the aluminum

pointer until the exhaust is cleanest. Tighten the shutter lock screw.



Figure 14

Shutter Lock

Screw