Connecting through a serial port, Figure 19, Cable to port connection – Nortel Networks MOG6xx User Manual

Page 87

Advertising
background image

87

Appendix B: WLAN Application Gateway 2246

Connecting through a serial port

1

Connect the WLAN Application Gateway 2246 to the serial port of a terminal or PC using a
DB-9 female, null-modem cable. See

Figure 19

.

Figure 19 Cable to port connection

2

Run a terminal emulation program (such as HyperTerminal™), or use a VT-100 terminal with
the following configuration:

— Bits per second: 9600
— Data bits: 8
— Parity: None
— Stop bits: 1
— Flow control: None

3

Reset the system.

The following appears on the terminal:

04830130

4

Type the following command using the terminal or PC keyboard:

0255CC [CTRL M] [CTRL J]

The command does not display on the screen as it is typed.

The login screen appears. If an error was made when entering the command string, the
message “Ill Formed Packet” appears. It appears as a series of numbers followed by some
form of the typed command. If this occurs, repeat Step 3 and Step 4.

Note:

If using Windows 2000, Service Pack 2 must be installed to enable the use of

HyperTerminal™.

RS-232
port

LAN

Ethernet

switch

RS-232

port

WLAN Application
Gateway 2246