Chapter 3 Software Overview

NI-VXI User Manual

3-66

© National Instruments Corporation

errors at times and valid results at other times. The

InitVXIlibrary

function automatically installs a default handler,

DefaultBusErrorHandler

, when it initializes the NI-VXI software.

Because bus errors can occur at any time, a corresponding enable and
disable function is not possible.

SetSoftResetHandler (func)

SetSoftResetHandler

replaces the current Soft Reset

interrupt handler with an alternate handler. A default handler,

DefaultSoftResetHandler

, is automatically installed when

InitVXIlibrary

initializes the NI-VXI software.

EnableSoftReset

must be called to enable writes to the Reset bit to

generate interrupts to the local CPU after the

InitVXIlibrary

call.

Note:

The Soft Reset interrupt does not apply to VME.

SetSysfailHandler (func)

SetSysfailHandler

replaces the current Sysfail interrupt handler

with an alternate handler. A Sysfail condition detected on the local
CPU generates an interrupt that calls the current Sysfail interrupt
handler. A default handler,

DefaultSysfailHandler

, is

automatically installed when

InitVXIlibrary

initializes the NI-VXI

software.

EnableSysfail

must be called to enable Sysfail interrupts

after the

InitVXIlibrary

call.

SetSysresetHandler (func)

SetSysresetHandler

replaces the current SYSRESET* interrupt

handler with an alternate handler. The

InitVXIlibrary

function

automatically installs a default handler,

DefaultSysresetHandler

,

when it initializes the NI-VXI software. Your application must then
call

EnableSysreset

to enable writes to the Reset bit to generate

interrupts to the local CPU.