Chapter 1 Overview of NI-VXI

NI-VXI User Manual

1-2

© National Instruments Corporation

Reserved

Reserved

Reserved

Reserved

Data Low

Data High

Response/Data
Extended

Protocol/Signal

Offset

Status/Control

Device Type

ID Register

VXI Configuration
Space

Offset

3F

20

IE

1C

1A

18

0E

0C

0A

08

06

04

02

00

• Upper 16 KB of A16

space reserved for
VXI configuration space

• 64 bytes per device

• 8-bit logical
address specifies
base address for
each device

• 256 devices per
VXI system

Device
Dependent
Registers

Reserved
by VXIbus
Specification

A32 Pointer Low

A32 Pointer High

A24 Pointer Low

A32 Pointer High

16

14

12

10

Shared Memory
Protocol
Registers

Communication
Registers
Required for VXI
Message-Based
Devices

Configuration
Registers
Required for all
VXI Devices

Figure 1-1.

VXI Configuration Registers

Register-Based Devices

Through the use of the VXI configuration registers, which are required
for all VXI devices, the system can identify each VXI device, its type,
model and manufacturer, address space, and memory requirements.
VXIbus devices with only this minimum level of capability are called
register-based devices. With this common set of configuration
registers, the centralized Resource Manager (RM), a software module,
can perform automatic system configuration when the system is