Table 3-3. signal descriptions – National Instruments NI PXIe-6672 User Manual

Page 19

Advertising
background image

Chapter 3

Hardware Overview

NI PXIe-6672 User Manual

3-6

ni.com

Table 3-3 outlines the function and direction of the signals discussed in
detail in the remainder of this chapter.

Table 3-3. Signal Descriptions

Signal Name

Direction

Description

PXI_CLK10_IN

Out

This is a signal that can replace the native 10 MHz oscillator
on the PXI backplane. PXI_CLK10_IN may originate from
the onboard TCXO or from an external source.

PXI_CLK10

In

This signal is the PXI 10 MHz backplane clock. By default,
this signal is the output of the native 10 MHz oscillator in the
chassis. An NI PXIe-6672 in the System Timing Slot can
replace this signal with PXI_CLK10_IN.

TCXO Clock

Out

This is the output of the 10 MHz TCXO. The TCXO is an
extremely stable and accurate frequency source.

CLKIN

In

CLKIN is a signal connected to the SMB input pin of the
same name. CLKIN can serve as PXI_CLK10_IN, a phase
lock reference for the TCXO, or as a source for routing to
PXI_STAR.

CLKOUT

Out

CLKOUT is the signal on the SMB output pin of the same
name. Either the TCXO clock, DDS clock, or PXI_CLK10
may be routed to this location.

DDS Clock

Out

This is the output of the DDS. The DDS frequency can be
programmed with fine granularity from 1 Hz to 105 MHz.
The DDS chip automatically phase-locks to PXI_CLK10.

PXI_STAR <0..16>

In/Out

The PXI star trigger bus connects the System Timing Slot to
all other slots in a star configuration. The electrical paths of
each star line are closely matched to minimize intermodule
skew. An NI PXIe-6672 in System Timing Slot can route
signals to all other slots using the star trigger bus.

PFI <0..5>

In/Out

The Programmable Function Interface pins on the
NI PXIe-6672 route timing and triggering signals between
multiple PXI chassis. A wide variety of input and output
signals can be routed to or from the PFI lines.

PXI_TRIG <0..7>

In/Out

The PXI trigger bus consists of eight digital lines shared
among all slots in the PXI chassis. The NI PXIe-6672 can
route a wide variety of signals to and from these lines.

Advertising