Glossar y – Napco Security Technologies GEM-P1664 User Manual

Page 33

Advertising
background image

L

NAPCO Security Systems

X

GEM-P1664 Installation Instructions

WI1424A 1/06



Page 33

security applications. When one or more zones is bypassed, the BYPASSED reminder on the GEM-RP1CAe2 keypad will display.
Disable Code Required for Easy Bypass is enabled by default.

Disable Function-Mode Download See Callback-Method Download

Disable Openings/Closings
Provides the flexibility of disabling openings and/or closings for any area(s).

Disable Handshake on Xmit (All Formats)
Causes data transmission to wait one second after dialing a pager telephone number before sending data.

Disable PGM2 Clear on Disarm
PGM2 will not clear when a user code is entered to disarm.

Disable System Trouble Audible Timeout
If the trouble occurs when disarmed, the sounder will now automatically time out in 10 minutes, without the need to press [RESET].
(MUST be programmed in UL installations)


Disable Wait-for-Silence (Pager Format)
Causes data transmission to start immediately after the pager telephone number.

Disable Zone Fault Scrolling/Disable Auto Status
Non 24-Hour Zones that are open (or shorted) normally display "

ZONE FAULTS

" (while disarmed) followed by the zone number(s) and

description(s). In high-security applications, program Disable Auto Status. Unsecured zones will then be indicated by a "

ZONE

FAULTED"

display without zone numbers displayed. Status may be displayed manually using the DISPLAY STATUS function.


Double Reporting See Report Telco 3

"E" Lugs (E5, E15, E19) (Do not program for UL installations)
E5 -
Lug E5 is used for Line Seizure. It is normally at 12V and when the telephone line is seized it goes to approximately 1V DC.
E15 - Lug E15 is used for Armed Status, either Armed Stay or Armed Away. When the system is armed it goes to approximately 1V

DC. For multiple area systems: If only 1 area, Lug E15 goes active low when area 1 is armed; if 4 areas, areas 1 through area 4
have to be armed for Lug E15 to go active low.

Lug E15 Area 1 Armed Away Only: When enabled, Lug E15 will activate when area 1 is armed Away. Note: If this
feature is not selected, the E15 Lug will, by default, activate when the system is armed (all areas).

E19 - Lug E19 is the Listen in Lug. It is an input and when it is forced low the panel will silence the keypad sounder and bell outputs

so that the Veri-phone can listen to activity at the residence. See Veri-Phone (WI783): Silence All Outputs During Audio
Session. Use Napco Part No. WL1 for field wiring.


Easy Exit (Not evaluated by UL)
While armed in the Interior Mode, Easy Exit can be initiated by pressing

D

or

U

. Easy Exit restarts the Exit delay, allowing a User

to exit an armed premises without disarming and rearming the system. Disable

D

or

U

buttons as Easy Exit.


Easy Programming of Auto download ID #'s and PC Preset Callback # (GEM-RP1CAe2/GEM-K1CA only)
It is now possible to set the PC Preset Auto download ID # and PC Preset Callback phone number from the GEM-RP1CAe2/GEM-
K1CA Easy Program Mode.

1. Enter Easy Program Mode and press PRIOR/NO until Central Phone # is displayed.
2. Program an "F" followed by the Auto Download ID # (2 digits) and then the Callback Telco # (up to 13 digits).
3. Press

U

to save.

4. Exit Program Mode ([RESET] [RESET]).
5. Enter Function Mode
6. Go to Function "ACTIVATE DOWNLOAD Y/N" and press NEXT/YES.
7. The panel will automatically call the PCPreset computer and download the program on the specified Auto DL line #.

Note: After the auto download of the control panel program, the system must be fully tested.