GEM-P1664 Installation Instructions

WI1424A 1/06



Page 37

JP1: Cut to enable Keypad Tamper.
JP3: Note different zone terminal wiring required as shown in wiring diagram.
W1 & W3: Cut both to disable touch pad backlighting.
W2: Cut to disable LCD backlighting.

Keypad Jumpers (GEM-RP2ASe2 / GEM-K2AS)
Refer to label LA1390 on the circuit board fishpaper for jumper locations and a summary of settings. See Section 3: Configuring the
GEM-RP2ASe2 Keypad for jumper selection.

Keypad Jumpers (GEM-RP3DGTL / GEM-K3DGTL)

Refer to label LA2090 on the circuit board fishpaper for jumper locations and a summary of settings. See Section 3: Configuring the
GEM-RP2ASe2 Keypad for jumper selection.

Keypad Jumpers (GEM-RP4 Series / GEM-K4 Series)
Refer to label LA2103 on the circuit board fishpaper for jumper locations and a summary of settings. See Section 3: Configuring the
GEM-RP2ASe2 Keypad for jumper selection.

Keypad Features
The following programmed system features will activate only if they have also been enabled at the keypad.

Ambush

Easy Arming

Access Control

Keypad (Police) Panic

Keypad Auxiliary Panic

Keypad Fire Panic


Keypad: GEM-K Series Keypads
Panel automatically detects the difference between the "Classic" and the K-Series ("STAY" and "AWAY") style keypads. Keypad #1
will determine this keypad type for the panel.

Keypad Panic
See Panic Zone

Keypad Sounder on Alarm
If a programmed zone goes into alarm, the keypad sounder will activate and will remain activated until the

C

button is pressed or

the system is disarmed.

Keypad Tamper See Tamper

Keypad Zone Directory
The GEM-RP1CAe2/GEM-K1 keypads will support the display of the Keypad Zone Directory. Press

A

or

R

until "DISPLAY

ZN DIRECTORY Y/N" is displayed and press [NEXT/YES]. Scroll through the zone directory by pressing [NEXT/YES] / [PRIOR/NO].

Keyswitch Arming; Maintained-Key Input Arming
The area will arm/disarm when the programmed zone is momentarily shorted (momentary keyswitch). To supervise the keyswitch,
program the zone for Day Zone on Open. Keyswitch Arming will be reported as User 68. Keyswitch must be provided with EOL
resistor. Maintained-key input arming will arm when shorted and disarm when opened.

Line-Reversal Module, M278
The Line-Reversal Module allows the panel to be monitored by a central station through leased lines. On alarm, the module reverses
normal line-voltage polarity. For details, refer to the instructions furnished with the module.

Loop Response See Zone Response Time


Low Battery; Wireless Low Battery; Keyfob Low Battery
A low-battery system trouble will annunciate at the keypad when the battery terminal voltage drops below normal. This condition may
signal a local sounding device, report to a central station (program Panel Low Bat Report Code), or both. If a battery is installed and
low terminal voltage is detected, a restore will not occur until the battery is recharged to its specified level and passes a dynamic test.
The dynamic test may be initiated manually by pressing the

C

button, or it will be initiated automatically, every four hours, by the

panel. In wireless installations, when displaying RF transmitter status, a "LoBatt" indication denotes a low-battery condition at the
transmitter.