For all ul installations, Specifications – Napco Security Technologies GEM-P1664 User Manual

Page 6

Advertising
background image

X

GEM-P1664 Installation Instructions

L

NAPCO Security Systems

WI1424A 1/06



Page 6

SPECIFICATIONS

GEM-P1664
O

perating Temperature: 0-49°C (32-120°F)

Input Power: 16.5-18.0 VAC via CLASS 2 Plug-In 20VA, 40VA or 50VA Transformer
Loop Voltage: 10-13Vdc
Loop Current: 3mA without Zone Doubling, 2.4mA with Zone Doubling using a 2.2K Ohm end-of-line resistor (Model EOL2.2K);

5mA for 2-wire smoke-detector zones; 1.4 mA using a 3.9K Ohm resistor (Model EOL3.9K) with Zone Doubling; 3mA with Se-
ries Zone with Loop Supervision
and 3mA with Series Zone Doubling with Loop Supervision

Loop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-detector zones
Alarm Voltage Output: 1
Programmable Negative Outputs: 2
Auxiliary Power Output: 11.7-12.5 VDC
Remote Power Output: 12 VDC regulated (for keypads)
Combined Standby Current (Remote Power + Aux. Power + Fire Power): See following charts.





















NOTE:

(1)

Alarm current can be increased by reducing standby current by the same amount.

* Not evaluated by UL.

** Commercial Burglary specifications not evaluated by UL.

16.5VAC

TRANSFORMER

BATTERY

(12 VDC)

STANDBY
CURRENT

ALARM

CURRENT

STANDBY

TIME

40VA/50VA

7 AH

550 mA

550 mA

(1)

4 Hours

20VA*

7 AH

500 mA

2.0 A

4 Hours

20VA*

7 AH

500 mA

2.0 A

6 Hours

RESIDENTIAL BURGLARY & COMMERCIAL BURGLARY**

16.5VAC

TRANSFORMER

BATTERY

(12 VDC)

STANDBY
CURRENT

ALARM

CURRENT

STANDBY

TIME

40VA/50VA

7 AH

120 mA

520 mA

(1)

24 Hours

40VA/50VA *

Two 7 AH

360 mA

280 mA

(1)

24 Hours

20VA *

7 AH

120 mA

360 mA

(1)

24 Hours

20VA *

Two 7 AH

360 mA

120 mA

(1)

24 Hours

COMBINATION RESIDENTIAL FIRE & RESIDENTIAL BURGLARY

Specifications

FOR ALL UL INSTALLATIONS

"ENABLE RESIDENTIAL FIRE" (ADDRESS 1422) MUST BE PROGRAMMED

The feature "Enable Residential Fire" (address 1422, option 4 / bit 3) must be programmed for ALL UL installations.
To program, please refer to the GEM-P1664 Programming Instructions (WI1422 and WI1423) for further information.

EZM Module: GEM-EZM816: Input, 50mA
Keypad Current: GEM-RP1CAe2: 100mA; 35mA if back lighting is disabled (cut W1, W2 & W3).

PGM Output: 5mA, 12V Special Application

Maximum Number of Keypads: 7
Maximum Wiring Length for each run (#22AWG): 1000' divided by total number of keypads and

EZMs on run

Keypad Dimensions: 4” x 5” x 1” (HWD); 11.1cm x 14.9cm x 2.7cm (HWD)

Advertising