Enable Alarm Output on Telco Fail only when Area(s) Armed (Alarm Output Only when Armed)

Allow Telephone Line Fault test to produce an Alarm Output only when armed. Note: requires "System Features: Alarm Output",
"Telco Fail" and version 9 or later panel.

Enable CP-01 Egress Tones Only
: Enable this feature if you want exit and entry sounds only--without setting any other CP-01 fea-
tures. When enabled, the Exit Delay keypad sounder (including the Exit Urgency sound during the final 10 seconds of the Exit Delay)
is enabled.

Enable CP-01 Limits

When enabled, three time limits are enabled as per the SIA CP-01 standards: (1) Exit Delay Time: If an attempt is made to change
the Exit Delay time to less than 45 seconds the time will be entered as 60 seconds. The maximum programmable time is 255 sec-
onds; (2) Entry Delay: If an attempt is made to change the Entry Delay time to less than 30 seconds the time will be entered as 30
seconds. The maximum programmable time is 255 seconds; and (3) Abort Delay: If an attempt is made to change the Abort Delay to
less than 15 seconds or more than 45 seconds the time will be entered as 30 seconds.
Note: In accordance with UL standards, the aggregate of the Entry Delay time and Abort Delay time "window" will not be pro-
grammed to exceed one minute. Note: When "Enable CP-01 Limits" is enabled, the Exit Delay keypad sounder (including the Exit
Urgency sound during the final 10 seconds of the Exit Delay) is enabled. Note: If "Enable CP-01 Limits" is enabled in EZ Program-
ming, any Zone in a Group will only activate an alarm and send a report ONCE. After the Zone has reported, it will remain in the
Group and may still initiate the Zone ANDing sequence.

Enable Keypad 1 Only Programming: In version 01 of the GEM-P1664 panel, programming is allowed from any keypad by default.
Program to restrict programming to Keypad #1 only, if needed.

Enable Local Alarm on First Zone "AND" Trip See Zone ANDing (Do not program in UL installations)

Enable TCP/IP Communications
Using the NetLink NL-MOD TCP/IP communications module accessory, the GEM-P1664 can report alarms via contact closures or via
its bell output but cannot report alarm data such as point ID information. The panel can, when the NL-MOD is visible on a network,
receive Windows Quickloader programming information or transmit panel log information over the network. Refer to the NL-Mod In-
stallation Instructions WI1242 for more information.

Enable Telephone Line Fault Test
Enable Line Fault Test will cause the panel to monitor the phone line. A failure will display as "

SYSTEM TROUBLE/E-08 SERVICE

" for

Telco Line Fail. Program this system trouble to activate the Burglary Output.

Enable 2-Count Swinger Shutdown See Swinger Shutdown

Exit/Entry Delay; Exit/Entry 1; Exit/Entry 2; Entry Relay
Delays permit exit and entry through the Entry/Exit Zone(s) after the system is armed without setting off an immediate alarm. Entry
delay allows the user time to enter and disarm the panel. Exit delay allows the user to leave the premises after the panel has been
armed. Unless the keypad has been configured otherwise, the sounder will come on and will pulse during the last 10 seconds of
entry delay to remind the user to disarm.
Two individually-programmable entry-delay times are provided to accommodate different entry zones. If two or more Exit/Entry
Zones are entered in succession, the delay programmed for the last Exit/Entry Zone entered will take precedence over all others.
Exit-Delay time and Entry-Delay time may each be programmed for up to 255 seconds (4 minutes). See Time Selection.
An external relay may be programmed to trip upon entry (see Programming Manual: Relay Event ID Codes, Area Entry Relays), and
remain on for a programmed duration.
Note: In UL installations, maximum exit delay is 60 seconds; maximum entry delay is 45 seconds. In UL Mercantile installations,
maximum entry delay is 60 seconds.
Entry delay may be canceled by pressing the

F

button prior to arming, however it will be restored automatically upon disarming.


Exit/Entry Follower
A zone programmed as an Exit/Entry Follower will ignore detection during the exit delay, and only during entry delay if the Exit/Entry
Zone is entered first. Thus, detection devices (passive infrared detectors, for example) along the path between the keypad and the
exit/entry door will not signal an alarm during exit/entry delay under normal conditions. However, if a device in the Exit/Entry Follower
Zone detects a violation when the exit/entry door has not first been entered, there will be no entry delay and the Exit/Entry Follower

Glossar

y

Example: Program an Auto Download ID # of 07 and a PC Preset Callback # of 1-516-842-9400

Go to Central Phone # input screen and press: [*] [5] [0] [7] [1] [5] [1] [6] [8] [4] [2] [9] [4] [0] [0] [ON/OFF]