Figure 16: linear heater layout overview, 19 figure 16: linear heater layout overview, Legend – Roberts Gorden Vantage twin Fire Unitary Infrared Heater TF-250 User Manual

Page 25

Advertising
background image

SECTION 7: H

EATER

I

NSTALLATION

19

FIGURE 16: Linear Heater Layout Overview

Burner

Reflector

Tube
Tube/Reflector

Hanger
Coupling

Assembly

LEGEND

a = 14" (36 cm)

reflector width (not shown)

b = 2" (5 cm)

end cap to burner

c = 2" (5 cm)

end cap to hanger

d = 7'6" (229 cm)

distance first hanger

e = 10' (305 cm)

distance between hangers

f = 9.5" (24 cm)

burner height

g = 23.5" (60 cm)

burner length

f

c

b

d

e

e

30' (9 m) Tube Length (Each Side)

g

f

c

b

d

e

e

e

40' (12 m) Tube Length (Each Side)

g

f

g

c

b

d

e

20' (6 m) Tube Length (Each Side)

c

b

d

e

e

e

e

50' (15 m) Tube Length (Each Side)

f

g

Linear layouts showing one side. Use same measurements for the other side.

Advertising